|
 |
|
We are engaged in providing a wide range of Sensor Transmitter that includes Air Velocity Sensor Transmitter, Temperature Indicators & Transmitters, Pressure / Vaccum Sensor Transmitter, Low Pressure Sensor Transmitter, Humidity / Temperature Sensor Transmitter etc.
|
 |  |  |  |  |
 | Air Velocity Sensor Transmitter Features of the Transmitter: - Air Velocity - Working Principle : the air velocity measurement is made with a hotwire, in constant thermal equilibrium. The temperature is maintained and measured with a PT 100 element.
- Measuring Range : 0 to 5m/s, 0 to 10m/s, 0 to 15m/s, 0 to 20m/s, 0 to 30m/s
- Units of measurement : m/s and fpm
- Accuracy: 3% of reading 0.3 m/s
- Response time : 1/e (63%) 2 sec.
- Type of Fluid Temperatue : air and neutral gases
- Measuring range : 0 to 50 °C, - 20 to 80 °C. -50 to 50 °C, 0 to 100 °C
- Units of measurement : C F Accuracy* : 0.5% of reading 0,4 C
- Response time : 1/e (63%) 5 sec.
- Resolution : 0.1 C
- Type of sensor : Pt100 class A as per DIN IEC751
- Type of fluid : air and neutral gases
Technical Specifications: - Output / Power supply active 0 - 10 V or 4 - 20 mA (power supply 24 Vac/Vdc ± 10 % )
- 3-4 wires maximum load : 500 Ohms (4 - 20 mA) minimum load : 1 K Ohms(0-10 V)
- Consumption 2 VA (0-10V) or max.22mA (4 - 20 mA)
- Electro-magnetical compatibility EN 61326
- Electrical connection screw terminal block for cable ø 1.5mm2 max
- Communication to PC Kimo RS 232 cable
- Working temperature (housing) 0 to 50 °C
- Working temperature (probe) 0 to 50 °C
- Stogare temperature -10 to 70 °C
- Environment air and neutral gases.
|  |  |  |  |  |  | Temperature Indicators & Transmitters Temperature Indicator & Controllers : - Input : RTD / Thermocouple J.K.R,S,T /4- 20 mA DC etc.
- OutPut: NO/NC Relay - ON/OFF
- Mains operated : 240VAC / 50 Hz Single & Two set Points
Temperature Transmitters : - Range:- 50 to 150 degree Celsius & upto 1200 degree
- Celsius Resolution : 0.1 & 1 degree Celsius fixed & Detachable probes in S.S
|  |  |  |  |  |  |  |
 | Pressure / Vaccum Sensor Transmitter Features: - Make MSI New High accuracy, Digitally compensated.
- One-piece EMI / RFI protected stainless steel construction.
- Isolated pressure transducer.
- 1% total Error Band, No leaks, No welds, No ‘OOO’ rings, No silicon oil Amplified output.
- Low pressure configuration.
Applications: - Pumps & Compressors
- Hydraulic/ Pneumatic systems Off road mobile equipment
- Energy & water management Pressure Instrumentation
- Refrigeration equipment Agriculture Equipment
- Train braking system.
Environmental: - Operating temperature range -40° to 100°C / Compensated temperature range –20°C to 85°C
- Total error band < /- 1% of FS (75-10,000PSI)
- Shock 50g, 11msec half sine shock per MIL standard 202F, method 213B, condition A
- Vibration /- 20g MIL-STD-810C,Procedure 514.2, curve L.
- EMI/RFI Immunity EN 50081-2, EN 50082-2 (10V/M, 26-1000MHz) , EN 61326 (Effective July 1, 2001)
- Humidity 95 % RH, condensing.
|  |  |  |  |  |  | Low Pressure Sensor Transmitter Features: - Pressure Working principle : a piezoresistve sensitive element creates a proportion voltage from the pressure applied on the sensor.
- Measuring range see "Part number"
- Unit of measurement Pa,mmH2O, mbar, in WG, mm HG(CP 101 and CP 102) m bar, in WG,mm HG, KPa, PSI(CP 103 and CP 104)
- Accuracy
- ±1.5 of reading ±3 Pa (CP 101)
- ± 1.5 % of reading ±3 mmH2O (CP 102)
- ± 1.5 % of reading ±3 mbar(CP 103 and CP 104)
- Response time 1/e(63%),0.3 sec
- Resolution 1 Pa - 0, 1 mmH2O-0,01 In HG(CP 101 and CP 102) 0,01mbar - 0,01,In WG - 0,01 mmHG - 0,1 KPa - 0,1 PSI (Cp 103 and CP 104)
- Autozero manual with push - button
- Type of fluid air and neutral gases
- Overpressure tolerated 25000 Pa (CP 101), 7000 mmH2O(CP 102)
- 1400 mbar(CP 103), 3000 mbar(CP 104)
- Available With or Without display
Features of the Housing ABS : - Fire-proof classification HB as per Ul 94
- Dimensions --
- Protection IP 65
- Display 5 digit LCD. Dimensions 50 X 50 mm
- Height of the digits 10 mm
- Connections Barbed fittings ø5.2 mm(CP 101 and CP 102)
- Compression fittings ø 4x6 (CP 103 and CP 104)
- Cable grip for cable ø7 mm max
- Weight 145g(with display) - 110 g (without display)
Technical Specifications: - Output/ Power supply active sensor 0 - 10 V ro 4-20 mA (power supply 24 Vdc ± 10%).
- 3-4 wires Passive loop 4-20mA (power supply 18/30 Vdc)
- 2 wires maximum, load : 500 Ohms(4 - 20 mA) minimum load : 1 K Ohms (010 V)
- Consumption 2 VA (0-10V) or max. 22 mA (4 - 20mA)
- Electro - magnetical compatiblity EN 61326
- Electircal connection screw terminal block for cables ø 1.5 mm2 max
- Communication to PC Kimo RS 232 cable
- Working temperature 0 to 50°C
- Storage temperature -10 to 70° C
- Enviroment air and neutral gases.
|  |  |  |  |  |  |  |
 | Humidity / Temperature Sensor Transmitter Features: - Rotronic hygromer capacitance sensors
- Accuracy and long term stability < 1. 5 % rh / per year max velocity 20 m/sec.
- Duct & wall mounting.
- IP 65 abs probe interchangeability
- Dew point & wet bulb temp. Operating temp. –50 to 200°c different types of filters.
Applications: - Hvac system building management system.
- Climatic test chambers paper industries.
- Hospital. Pharmaceutical industries. Cold storages. Museum / libraries & research. Industrial process monitoring.
|  |
|